Column Name | Description | Data Type | Length | Allow Nulls | Default |
BF_RID | ID-No. of the buffer | Integer | 4 |
| 0 |
BF_MF_RID | ID-No. of the manufacturer | Integer | 4 | ✓ | 0 |
BF_DESC | Description of the buffer | VarWChar | 50 | ✓ |
|
BF_SUB_DESC | Sub-description of the buffer for detailed information | VarWChar | 75 | ✓ |
|
BF_PG_GRP | N of the profile-group construction for the corresponding car frame. pData[0] = m_pBufferSet->m_BF_D; pData[1] = m_BF_H_Edit; pData[2] = m_BF_DELTA_H_Edit; pData[3] = m_BF_BASE_H_Edit; pData[4] = m_BF_BASE_D_Edit; pData[5] = m_BF_TRAVEL_Edit; pData[6] = m_pBufferSet->m_BF_FIXED_SOCKET_H; pData[7] = m_pBufferSet->m_BF_K1_H; pData[8] = m_pBufferSet->m_BF_BASE_K2_H; pData[9] = 0; // Added: 16.7.2004 pData[10] = m_pBufferSet->m_BF_FIXED_SOCKET_D; // Added: 16.7.2004 pData[50] = m_pBufferSet->m_BF_USER_PG_50; pData[51] = m_pBufferSet->m_BF_USER_PG_51; pData[52] = m_pBufferSet->m_BF_USER_PG_52; pData[53] = m_pBufferSet->m_BF_USER_PG_53; pData[54] = m_pBufferSet->m_BF_USER_PG_54; | Integer | 4 | ✓ | 0 |
BF_TYPE | Types of the buffer: 1 - rubber or plastic 2 - hydraulic 3 - spring | SmallInt | 2 | ✓ | 0 |
BF_D | Diameter of the buffer | Double | 9 | ✓ | 0 |
BF_FIXED_SOCKET_H | Height of the socket plate from the pipe below buffer | Double | 9 | ✓ | 0 |
BF_DELTA_H | Length of the pipe below the spring- or oil-buffer | Double | 9 | ✓ | 0 |
BF_DELTA_D | Diameter of the pipe below the spring- or oil-buffer | Double | 9 | ✓ | 0 |
BF_K1_H | Height of the buffer impact plate | Double | 9 | ✓ | 0 |
BF_K1_D | Diameter of the buffer impact plate | Double | 9 | ✓ | 0 |
BF_H_UNCOMPRESSED | Free spring length - height when buffer is uncompressed | Double | 9 | ✓ | 0 |
BF_H_COMPRESSED | Length of the spring when car or counterweight strikes on buffer | Double | 9 | ✓ | 0 |
BF_H_COMPRESSED_MIN | Length of the spring when maximal compressed | Double | 9 | ✓ | 0 |
BF_MODE | Mode whether the buffer has to be extended or the buffer base and how to calculate the length: 0x0001 — Calculate the length of BF_DELTA_H automatically, if this bit is set, the buffer base can be edited by the user and the length of BF_DELTA_H will be calculated automatically. In the other case the height of the buffer base will be calculated (typical behavior). | SmallInt | 2 | ✓ | 0 |
BF_TRAVEL | Maximum stroke of the buffer | Double | 9 | ✓ | 0 |
BF_BASE_D | Diameter of the buffer base | Double | 9 | ✓ | 0 |
BF_PART_NO | Item-No., Order No. or similar number which identifies the part | VarWChar | 30 | ✓ |
|
BF_BASE_K2_D | Diameter of the under construction of the buffer base | Double | 9 | ✓ | 0 |
BF_BASE_K2_H | Height of the under construction of the buffer | Double | 9 | ✓ | 0 |
BF_USER_PG_50 | Used for rectangular socket when BF_MODE 0x0256 is active. | Double | 9 | ✓ | 0 |
BF_USER_PG_51 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_52 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_53 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_54 |
| Double | 9 | ✓ | 0 |
BF_FIXED_SOCKET_D | Diameter of the socket plate from the pipe below buffer. BF_MODE 0x0256 for a square shape. | Double | 9 | ✓ | 0 |
BF_USER_PG_55 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_56 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_57 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_58 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_59 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_60 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_61 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_62 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_63 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_64 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_65 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_66 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_67 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_68 |
| Double | 9 | ✓ | 0 |
BF_USER_PG_69 |
| Double | 9 | ✓ | 0 |
L_BufferTab