Column Name | Description | Data Type | Length | Allow Nulls | Default |
CY_RID | ID-No. of the jack | Integer | 4 |
| 0 |
CY_MF_RID | ID-No. of the manufacturer | Integer | 4 | ✓ | 0 |
CY_DESC | Description of the hydraulic jack type | VarWChar | 50 | ✓ |
|
CY_SUB_DESC | Sub-description of the hydraulic jack for detailed information | VarWChar | 75 | ✓ |
|
CY_PG_GRP | ID-No. of the profile-group | Integer | 4 | ✓ | 0 |
CY_CB_GRP | Related to: CB_GRP | Integer | 4 | ✓ | 0 |
CY_TYPE | Hydraulic jack installation position: 0 - built in a borehole 1 - standing up | SmallInt | 2 | ✓ | 0 |
CY_YG_RID_1 |
| Integer | 4 | ✓ | 0 |
CY_YG_RID_2 |
| Integer | 4 | ✓ | 0 |
CY_CSU_RID | Related to: CSU_RID | Integer | 4 | ✓ | 0 |
CY_STEP_NO | Number of the jack stages | SmallInt | 2 | ✓ | 0 |
CY_A | Height of the towered jack head | Double | 9 | ✓ | 0 |
CY_AA | Obsolete | Double | 9 | ✓ | 0 |
CY_B | Distance between the upper edge of the jack head and the assembly plate: Value — Explanation | Double | 9 | ✓ | 0 |
CY_B1 | Distance between the upper edge of the jack head and the bottom edge of the assembly ring | Double | 9 | ✓ | 0 |
CY_C | Diameter of jack pipe coupling | Double | 9 | ✓ | 0 |
CY_C1 |
| Double | 9 | ✓ | 0 |
CY_C2 |
| Double | 9 | ✓ | 0 |
CY_C3 |
| Double | 9 | ✓ | 0 |
CY_C4 |
| Double | 9 | ✓ | 0 |
CY_D1 | Diameter of the first ram | Double | 9 | ✓ | 0 |
CY_D2 | Diameter of the second ram | Double | 9 | ✓ | 0 |
CY_D3 | Diameter of the third ram | Double | 9 | ✓ | 0 |
CY_E | Diameter of the first reinforcement ring | Double | 9 | ✓ | 0 |
CY_FF | Only hydraulic jacks with three stages: diameter of the second reinforcement ring | Double | 9 | ✓ | 0 |
CY_G | Diameter of the reinforcement rings two stages jacks — three stages jacks | Double | 9 | ✓ | 0 |
CY_KW | Ram wall thickness | Double | 9 | ✓ | 0 |
CY_KW2 | Wall thickness of the second plunger | Double | 9 | ✓ | 0 |
CY_KW3 | Wall thickness of the third plunger | Double | 9 | ✓ | 0 |
CY_ZW | Jack wall thickness | Double | 9 | ✓ | 0 |
CY_BT | Base thickness | Double | 9 | ✓ | 0 |
CY_G1 | Jack weight at zero stroke | Double | 9 | ✓ | 0 |
CY_G2 | Jack weight per meter stroke | Double | 9 | ✓ | 0 |
CY_G3 | Weight of jack in 0-position | Double | 9 | ✓ | 0 |
CY_G4 | Weight of jack for each meter of travel | Double | 9 | ✓ | 0 |
CY_H | Outer diameter | Double | 9 | ✓ | 0 |
CY_H1 |
| Double | 9 | ✓ | 0 |
CY_H2 | Length of CY_H1 | Double | 9 | ✓ | 0 |
CY_I | Radius of gyration | Double | 9 | ✓ | 0 |
CY_J | Moment of inertia [mm4] | Double | 9 | ✓ | 0 |
CY_K | Factor k from formula: length = t + stroke / k | Double | 9 | ✓ | 0 |
CY_L | Distance between jack center axis and axis of leakage oil return | Double | 9 | ✓ | 0 |
CY_N1 | Distance between oil feed pipe and outer edges of the jack: Value — Explanation | Double | 9 | ✓ | 0 |
CY_O | Thickness of the assembly plate or foot plate | Double | 9 | ✓ | 0 |
CY_R | Diameter of the SAE welding flange (inch values) | Double | 9 | ✓ | 0 |
CY_S | Screw diameter of the jack head | Double | 9 | ✓ | 0 |
CY_T | Factor t from formula: Length = t + stroke/k | Double | 9 | ✓ | 0 |
CY_VG |
| Double | 9 | ✓ | 0 |
CY_VZ | Whole positioning footplate | Double | 9 | ✓ | 0 |
CY_VP |
| Double | 9 | ✓ | 0 |
CY_PM |
| Double | 9 | ✓ | 0 |
CY_PMK |
| Double | 9 | ✓ | 0 |
CY_BUCKLING_CALC | Buckling resistance | Double | 9 | ✓ | 0 |
CY_E_MODULE | Value of the elasticity modulus [N/mm] | Double | 9 | ✓ | 0 |
CY_P_STATIC_MIN_CALC | Min. static oil pressure | Double | 9 | ✓ | 0 |
CY_P_STATIC_MAX_CALC | Max. static oil pressure | Double | 9 | ✓ | 0 |
CY_VG_CALC | Required transfer current for speed = 1 m/s | Double | 9 | ✓ | 0 |
CY_VP_CALC | Circulating oil quantity per meter of stroke [l/m] | Double | 9 | ✓ | 0 |
CY_VZ_CALC | Oil for filling per meter [l/m] | Double | 9 | ✓ | 0 |
CY_WEIGHT_CALC | Calculated weight for hydraulic jack | Double | 9 | ✓ | 0 |
CY_RB_DISALLOWED_TOP | Disallowed distance for rail bracket at the top | Double | 9 | ✓ | 0 |
CY_RB_DISALLOWED_BOTTOM | Disallowed distance for rail bracket at the bottom | Double | 9 | ✓ | 0 |
CY_BT_U1 | Base thickness under groove | Double | 9 | ✓ | 0 |
CY_BT_R1 |
| Double | 9 | ✓ | 0 |
CY_BT_H1 |
| Double | 9 | ✓ | 0 |
CY_BT_S1 |
| Double | 9 | ✓ | 0 |
CY_BT_H2 |
| Double | 9 | ✓ | 0 |
CY_BT_CL_R2 |
| Double | 9 | ✓ | 0 |
CY_BT_SL_R2 |
| Double | 9 | ✓ | 0 |
CY_BT_U3 |
| Double | 9 | ✓ | 0 |
CY_BT_R3 |
| Double | 9 | ✓ | 0 |
CY_CYL_RP02 |
| Double | 9 | ✓ | 0 |
CY_CYL_RM | Tensile strength of material in [N/mm] | Double | 9 | ✓ | 0 |
CY_PL_RP02 | Proof stress (non-proportional elongation) of hydraulic jack material [N/mm] | Double | 9 | ✓ | 0 |
CY_PL_RM |
| Double | 9 | ✓ | 0 |
CY_MASSEQUIPMENT |
| Double | 9 | ✓ | 0 |
CY_PL0Stroke1 |
| Double | 9 | ✓ | 0 |
CY_PL0Stroke2 |
| Double | 9 | ✓ | 0 |
CY_PL0Stroke3 |
| Double | 9 | ✓ | 0 |
CY_PART_NO |
| VarWChar | 50 | ✓ |
|
CY_USER_PG_50 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_51 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_52 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_53 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_54 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_55 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_56 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_57 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_58 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_59 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_60 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_61 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_62 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_63 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_64 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_65 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_66 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_67 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_68 |
| Double | 9 | ✓ | 0 |
CY_USER_PG_69 |
| Double | 9 | ✓ | 0 |
L_CylinderDimTab
Written by Julien