Prerequisites
The fixing points now position themselves automatically at the shaft wall and at the correct top/bottom location on the landing door.
Steps
1.) Select the manufacturer's common left and right fixing points. In DigiPara Liftdesigner Datamanager, open the Common Components manufacturer module and mark the left and right fixing point columns by holding Shift key and selecting both. Press Ctrl+C to start a manual copy process for the data rows.
2.) Paste the data rows into your own new fixing group. Switch back to your manufacturer module (in this case 75:LD-Developer). Press the plus symbol to open the table. Then, click on the last existing data row and press Ctrl+V to insert the new data rows.
3.) Define the position of the left and right fixing points in Z-direction. Set the Z-direction position for both the left and right fixing points.
4.) Determine the door width range. Set the door width range these left/right fixing points apply to.
Result
The landing door's fixing group now also includes correctly positioned left and right fixing points, reused from the shared Common Components module.
Next Step