Prerequisites
A project is open, with landing doors already present in the shaft.
Landing door fixing points active.
Set the landing door dimensions
Steps
Activate the landing door properties.
Select the landing door directly in the project or in a view frame.Adapt individually or in group.
Choose whether changes apply to all landing doors on the current shaft wall (Modify with group) or to the selected door only (This door is different).Set the door dimensions.
Height — predefined height list from the database or input field.
Width — selects a different, predefined manufacturer-specific width for the current landing door model.
Extended door dimension — extra dialog to modify the predefined landing door dimensions individually.
Distance Sill to Wall — the distance between the landing door sill front and the wall.
Result: The landing door has the dimensions and sill-to-wall distance you set.
Configure the jamb
Steps
Select a jamb model from the database.
Select the jamb under the Parent Entry object in the project via data tree or breadcrumb. Choose a the jamb wanted from the Select Product window.Adapt individually or in group.
Choose whether your settings apply to all jambs (Modify with group) or to the selected jamb only (This jamb is different).Create a user defined design.
Set User defined design to Yes to enable the Extended jamb dimensions dialog and modify the jamb design individually, or leave it at No to use the standard jamb design.
Result: The jamb uses the design (standard or individually modified) and grouping you configured.
Position the landing door fixing points
Steps
Select the door fixing point list to display.
The landing door has four fixing brackets lists: Top (0), Bottom (1), Left (2), and Right (3). Click the door or the specific fixing component to activate the properties.Set up door fixing points quantity.
Choose Manually to set the count of fixing points.Activate anchor rails for the fixing brackets.
Under Fixing Options:One large anchor rail — use a single large anchor rail for the door fixing instead of individual points.
Arrange manually — set to Yes to position the anchor rail relative to the fixings in the current row manually.
Adjust the fixing point.
Set the Grouping options, the Location to Manually to edit its X0, Y0, Z0 position and the P2-X / P2-Z displacement of its small anchor rail, and optionally set Fixing points in the wall pockets to Yes to create a wall pocket for it, sized via DX, DY, DZ.
Result: The landing door's fixing points are arranged — automatically or manually — in the lists and positions you configured.