Prerequisites
Shaft groups can be repositioned and aligned.
Steps
1.) Understand automatic machine room combination. When adding another elevator to the group, the machine rooms are automatically combined, and duplicate or unneeded components — such as a second machine room door or a second ventilation window — are automatically removed.
2.) Configure machine room(s) via the Group and Shaft Configurator. It's recommended to calculate the machine room size after adding elevators to the group.
3.) Adjust machine room size and position. Edit the displayed Position and Size values. The reference point is the shaft base point (Shaft0.).
4.) Set separate machine rooms for each shaft, if needed. Remove the check mark to allow individual machine room settings per shaft.
Result
You understand how machine rooms combine automatically when adding elevators, and can configure their size, position, and — if needed — keep them separate per shaft.
Next Step
Related Video Tutorial