Column Name | Description | Data Type | Length | Allow Nulls | Default |
DTMR_RID | RID number of the machine room | Integer | 4 |
| 0 |
DTMR_GRP | Number of the machine room group | Integer | 4 | ✓ | 0 |
DTMR_IX | Index for the different possible machine rooms: 1 - Option 1 2 - Option 2 3 - Option 3 4 - Option 4 | SmallInt | 2 | ✓ | 0 |
DTMR_DESC | Description of the machine room | VarWChar | 75 | ✓ |
|
DTMR_SUB_DESC | Sub-description of the machine room | VarWChar | 75 | ✓ |
|
DTMR_MR_WIDTH | Width of the machine room | Double | 9 | ✓ | 0 |
DTMR_MR_DEPTH | Depth of the machine room | Double | 9 | ✓ | 0 |
DTMR_MR_DX_K0 | Constant for the position of the machine room in x-direction. Formula for the positioning of the machine room in x-direction: | Double | 9 | ✓ | 0 |
DTMR_MR_DX_F0 | Factor for the position of the machine room in x-direction. Formula for the positioning of the machine room in x-direction: | Double | 9 | ✓ | 0 |
DTMR_MR_DY_K0 | Constant for the position of the machine room in y-direction. Formula for the positioning of the machine room in y-direction: | Double | 9 | ✓ | 0 |
DTMR_MR_DY_F0 | Factor for the position of the machine room in y-direction. Formula for the positioning of the machine room in y-direction: | Double | 9 | ✓ | 0 |
DTMR_DOOR_RID | RID number of the machine room door | Integer | 4 | ✓ | 0 |
DTMR_DOOR_WALL | Number of the wall at which the machine room door is installed | SmallInt | 2 | ✓ | 0 |
DTMR_DOOR_DXY | Distance between outside MR door and wall | Double | 9 | ✓ | 0 |
DTMR_PANEL_1_WALL | Wall where the back side of the panel shows to | SmallInt | 2 | ✓ | 0 |
DTMR_PANEL_1_WALL_CLR | Distance between the back side of panel and the wall which is defined under DTMR_PANEL_1_WALL | Double | 9 | ✓ | 0 |
DTMR_PANEL_1_X0_WALL | Wall where the side of the panel shows to | SmallInt | 2 | ✓ | 0 |
DTMR_PANEL_1_X0_DELTA | Distance between the side of panel and the wall which is defined under DTMR_PANEL_1_X0_WALL | Double | 9 | ✓ | 0 |
DTMR_PANEL_2_WALL | Wall where the back side of the panel shows to | SmallInt | 2 | ✓ | 0 |
DTMR_PANEL_2_WALL_CLR | Distance between the back side of panel and the wall which is defined under DTMR_PANEL_2_WALL | Double | 9 | ✓ | 0 |
DTMR_PANEL_2_X0_WALL | Wall where the back side of the panel shows to | SmallInt | 2 | ✓ | 0 |
DTMR_PANEL_2_X0_DELTA | Distance between the back side of panel and the wall which is defined under DTMR_PANEL_2_X0_WALL | Double | 9 | ✓ | 0 |
DTMR_FAN_RID | RID number of the exhaust fan | Integer | 4 | ✓ | 0 |
DTMR_FAN_WALL | Number of the wall at which the exhaust fan is installed | SmallInt | 2 | ✓ | 0 |
DTMR_FAN_DXY | Distance between the IP (insert point) of the wall and the first outside of the exhaust fan | Double | 9 | ✓ | 0 |
DTMR_VENT_RID | RID number of the ventilation window | Integer | 4 | ✓ | 0 |
DTMR_VENT_WALL | No. of the wall at which the ventilation window is installed | SmallInt | 2 | ✓ | 0 |
DTMR_VENT_DXY | Distance between the IP (insert point) of the wall and the first outside of the ventilation window | Double | 9 | ✓ | 0 |
DTMR_DUCTHOLE_DX | Width of the duct hole in x-direction | Double | 9 | ✓ | 0 |
DTMR_DUCTHOLE_DY | Width of the duct hole in y-direction | Double | 9 | ✓ | 0 |
DTMR_DUCTHOLE_X0_DELTA | Distance between shaft wall which is defined at DTMR_DUCTHOLE_X0_WALL and duct hole in x-direction | Double | 9 | ✓ | 0 |
DTMR_DUCTHOLE_Y0_DELTA | Distance between shaft wall which is defined at DTMR_DUCTHOLE_Y0_WALL and duct hole in y-direction | Double | 9 | ✓ | 0 |
DTMR_DUCTHOLE_X0_WALL | Number of the wall which refers to the distance DTMR_DUCTHOLE_X0_DELTA in x-direction. Possible entries: 3 - Left wall 4 - Right wall | Double | 9 | ✓ | 0 |
DTMR_DUCTHOLE_Y0_WALL | Number of the wall which refers to the distance DTMR_DUCTHOLE_Y0_DELTA in y-direction. Possible entries: 1 - Bottom wall 2 - Top wall | Double | 9 | ✓ | 0 |
DTMR_PRB_RID | RID number of the power receiving box | Integer | 4 | ✓ | 0 |
DTMR_PRB_WALL | No. of the wall at which the power receiving box is fixed | SmallInt | 2 | ✓ | 0 |
DTMR_PRB_DXY | Distance between the IP (insert point) of the wall and the center line of the power receiving box | Double | 9 | ✓ | 0 |
DTMR_LP_RID | RID number of the lighting outlet | Integer | 4 | ✓ | 0 |
DTMR_LP_WALL | Number. of the wall at which the lighting outlet/machine room lamp is fixed | SmallInt | 2 | ✓ | 0 |
DTMR_LP_DXY | Distance between the IP (insert point) of the wall and the first outside of the lighting outlet | Double | 9 | ✓ | 0 |
DTMR_LOCATION | Mode for the alignment of the machine room: 1 - Front wall 2 - Rear wall 3 - Left wall 4 - Right wall | Integer | 4 | ✓ | 0 |
DTMR_WALL_1_THICKNESS | Thickness of wall 1 | Double | 9 | ✓ | 0 |
DTMR_WALL_2_THICKNESS | Thickness of wall 2 | Double | 9 | ✓ | 0 |
DTMR_WALL_3_THICKNESS | Thickness of wall 3 | Double | 9 | ✓ | 0 |
DTMR_WALL_4_THICKNESS | Thickness of wall 4 | Double | 9 | ✓ | 0 |
DTMR_WALL_TOP_THICKNESS | Thickness of the top | Double | 9 | ✓ | 0 |
DTT_MFSUP_RID | RID number and description of the manufacturer supplier | Integer | 4 |
| 0 |
L_DTColDwgMRTab