Column Name | Description | Data Type | Length | Allow Nulls | Default |
DTH_RID | RID number of the horizontal dimension record | Integer | 4 |
| 0 |
DTH_DTD_RID | RID number to the corresponding drawing record in the L-DTColDwgTab | Integer | 4 | ✓ | 0 |
DTH_DESC | Description of the horizontal dimension record | VarWChar | 200 | ✓ |
|
DTH_RB_CW_Y1 | Distance between wall and centerline of the counterweight | Double | 9 | ✓ | 0 |
DTH_W2DIST | Distance between wall 2 and the rear side of the car | Double | 9 | ✓ | 0 |
DTH_W3DIST | Distance between wall 3 and the left side of the car | Double | 9 | ✓ | 0 |
DTH_W4DIST | Distance between wall 4 and the right side of the car | Double | 9 | ✓ | 0 |
DTH_RB_CW_SEPBEAM_DIST | Distance between counterweight-rail bracket and the separator-beam | Double | 9 | ✓ | 0 |
DTH_CW_WALL | Number of the wall at which the counterweight is fixed: 2- Rear drop counterweight 3 - Left drop counterweight 4 - Right drop counterweight For all hydraulic types DTH_CW_WALL should be set to -1 Exception: L-types In this case DTH_CW_WALL contains the wall number = 2...4; wall 1 = L-Type at front wall is not supported. | SmallInt | 2 | ✓ | 0 |
DTH_DTV_GRP | Number of the variable group in the DTVarTab | Integer | 4 | ✓ | 0 |
DTH_CW_SAFETY | Option for counterweight with or without safety: 0 - without safety -1 - with safety | SmallInt | 2 | ✓ | 0 |
DTH_CW_RID | RID number of the counterweight | Integer | 4 | ✓ | 0 |
DTH_CW_SUBWEIGHT_COUNT | Quantity of the counterweight inlets | Integer | 4 | ✓ | 0 |
DTH_CW_GD_RID | RID number of the guide rail for the counterweight | Integer | 4 | ✓ | 0 |
DTH_RB_RID | RID number of the rail bracket only used by counterweight | Integer | 4 | ✓ | 0 |
DTH_RB_COMBI_RID | RID number of the rail bracket used by counterweight and car. This variable always has to be inserted. | Integer | 4 | ✓ | 0 |
DTH_CW_GS_RID_TOP | RID number of the guide shoe at the top of the counterweight | Integer | 4 | ✓ | 0 |
DTH_CW_GS_RID_BOTTOM | RID number of the guide shoe at the bottom of the counterweight | Integer | 4 | ✓ | 0 |
DTH_CW_DELTA | Displacement between car and counterweight | Double | 9 | ✓ | 0 |
DTH_CAR_SG_MODE | Location of the rope fixing point of the counterweight safety gear: 0 - Left bottom 1 - Left top 2 - Right top 3 - Right bottom
| SmallInt | 2 | ✓ | 0 |
DTH_CAR_GOV_ALPHA | Angle of the car governor (valid from 0 to 360 degrees). The angle is always an absolute value. | Double | 9 | ✓ | 0 |
DTH_CW_SG_MODE | Location of the rope fixing point of the car safety gear: 0 - Right top 1 - Right bottom 2 - Left bottom 3 - Left top | SmallInt | 2 | ✓ | 0 |
DTH_CW_GOV_ALPHA | Angle of the counterweight governor (valid from 0 to 360 degrees). The angle is always an absolute value. | Double | 9 | ✓ | 0 |
DTH_LT_RID | RID number of the pit ladder | Integer | 4 | ✓ | 0 |
DTH_LT_WALL | Number of the wall at which the pit ladder is fixed | SmallInt | 2 | ✓ | 0 |
DTH_LT_DXY | Distance between the IP (insert point) of the wall and the first outside of the pit ladder | Double | 9 | ✓ | 0 |
DTH_LP_RID | RID number of the shaft lamp | Integer | 4 | ✓ | 0 |
DTH_LP_WALL | Number of the wall at which the pit ladder is fixed | SmallInt | 2 | ✓ | 0 |
DTH_LP_DXY | Distance between the IP (insert point) of the wall and the center line of the shaft lamp | Double | 9 | ✓ | 0 |
DTH_TC_RID | RID number of the traveling cable | Integer | 4 | ✓ | 0 |
DTH_TC_WALL | No. of the wall, at which the traveling cable is fixed | SmallInt | 2 | ✓ | 0 |
DTH_TC_DXY | Distance between the IP (insert point) of the wall and the center line of the traveling cable part, which is fixed at the wall | Double | 9 | ✓ | 0 |
DTH_HOLE_TR_DX | Size of the hole for the rope of the traction sheave in x-direction | Double | 9 | ✓ | 0 |
DTH_HOLE_TR_DY | Size of the hole for the rope of the traction sheave in y-direction | Double | 9 | ✓ | 0 |
DTH_HOLE_TR_DX0 | Displacement between the center-point of the rope and the center point of the hole for the rope of the traction sheave in x-direction | Double | 9 | ✓ | 0 |
DTH_HOLE_TR_DY0 | Displacement between the center-point of the rope and the center point of the hole for the rope of the traction sheave in y-direction | Double | 9 | ✓ | 0 |
DTH_HOLE0_DEF_DX | Size of the first hole for the rope of the deflection sheave in x-direction | Double | 9 | ✓ | 0 |
DTH_HOLE0_DEF_DY | Displacement between the center-point of the rope and the center point of the first hole for the rope of the deflection sheave in y-direction | Double | 9 | ✓ | 0 |
DTH_HOLE0_DEF_DX0 | Displacement between the center-point of the rope and the center point of the first hole for the rope of the deflection sheave in x-direction | Double | 9 | ✓ | 0 |
DTH_HOLE0_DEF_DY0 | Displacement between the center-point of the rope and the center point of the first hole for the rope of the deflection sheave in y-direction | Double | 9 | ✓ | 0 |
DTH_HOLE1_DEF_DX | If necessary, size of the second hole for the rope of the deflection sheave in x-direction | Double | 9 | ✓ | 0 |
DTH_HOLE1_DEF_DY | If necessary, size of the second hole for the rope of the deflection sheave in y-direction | Double | 9 | ✓ | 0 |
DTH_HOLE1_DEF_DX0 | If necessary, displacement between the center-point of the rope and the center point of the second hole for the rope of the deflection sheave in x-direction | Double | 9 | ✓ | 0 |
DTH_HOLE1_DEF_DY0 | If necessary, displacement between the center-point of the rope and the center point of the second hole for the rope of the deflection sheave in y-direction | Double | 9 | ✓ | 0 |
DTH_DOOR_POSITIONS | Bit connecting for fixing the possible door positions: 1 — the door at wall 1 will be drawn as default For example: = 1 + 16 + 32 = 49 | SmallInt | 2 | ✓ | 0 |
DTH_DTMR_GRP | Related to: DTMR_GRP | Integer | 4 | ✓ | 0 |
DTH_SHAFT_DD_RID | Related to: SHAFT_DD_RID | Integer | 4 | ✓ | 0 |
DTH_JTS_GRP_WALL_1 | No. of the group for the location of the hall buttons for the front wall | Integer | 4 | ✓ | -1 |
DTH_JTS_GRP_WALL_2 | No. of the group for the location of the hall buttons for the rear wall | Integer | 4 | ✓ | -1 |
DTH_JTS_GRP_WALL_3 | No. of the group for the location of the hall buttons for the left wall | Integer | 4 | ✓ | -1 |
DTH_JTS_GRP_WALL_4 | No. of the group for the location of the hall buttons for the right wall | Integer | 4 | ✓ | -1 |
DTH_VENT_RID | RID number of the ventilation | Integer | 4 | ✓ | 0 |
DTH_VENT_WALL | No. of the wall, at which the ventilation is fixed 1 - Front wall 2 - Rear wall 3 - Left wall 4 - Right wall 5 - Ceiling | SmallInt | 2 | ✓ | 0 |
DTH_VENT_DXY | Distance between the IP (insert point) of the wall and the center line of the ventilation part, which is fixed at the wall | Double | 9 | ✓ | 0 |
DTT_MF_RID | RID number of the manufacturer module | Integer | 4 |
| 0 |
DTT_MFSUP_RID | RID number and description of the manufacturer supplier | Integer | 4 |
| 0 |
L_DTColDwgHorTab