Skip to main content

L_DoorFixingPointTab

Written by Julien

Column Name

Description

Data Type

Length

Allow Nulls

Default

DFP_RID

ID-No. of the door fixing point
​
(ID-No.=RID number of the door fixing point)
consecutive number

Integer

4

0
​

DFP_GRP

Number of the group of the door fixing point

Integer

4

✓

0
​

DFP_IX

Counter for the quantity of the dimension records for the same type of fixing.

  • Starts always with 0, then count up to the last record! The next group starts again with 0.

Integer

4

✓

0
​

DFP_MODE

Integer

4

✓

0
​

DFP_TYPE

Type of the door fixing points:

0 - top fixing point

1 - bottom fixing point

2 - left fixing point

3 - right fixing point

SmallInt

2

✓

0
​

DFP_DX

Alignment in x-direction.

Do not use this field any more for new records. Use DFP_DX_RULE instead. This can dramatically reduce the number of records to be loaded. Fill this field with 0.

Double

9

✓

0
​

DFP_DY

Alignment in y-direction. Do not use this field any more for new records. See also DFP_DX.

Double

9

✓

0
​

DFP_DZ

Alignment in z-direction. Do not use this field any more for new records. See also DFP_DX.

Single

4

✓

0
​

DFP_DX_RULE

Instead of filling fixed DFP_DX values, you may enter a rule into this field.

You can use the same syntax as it is allowed as profile parameters.

Example:

It is, for instance, very common that a fixing point is at DW/2 - 100 mm (from the center of the door).

In this case you may enter the following rule in the DFP_DX_RULE field:

0.5*[3]-100

  • For a specific record you must decide whether to use rules or not. The parameter "Apply Rules"(32) must be set in DFP_MODE. If set, you must also fill proper values into DFP_DY_RULE and DFP_DZ_RULE.

You can use the standard profile parameters for door fixing points, especially:

[3] = Door width

[7] = Door height

[4] = P2_DELTA_DX

If you want to re-use door parameters at the fixing points, you need to use the mapped door fixing point parameters instead (limited to 10 parameters, see below).

Door User Parameter — Internally mapped to Door Fixing point parameter
[50] -> DD_USER_PG_50 — [60] -> DF_USER_PG_60
[51] -> DD_USER_PG_51 — [61] -> DF_USER_PG_61
[52] -> DD_USER_PG_52 — [62] -> DF_USER_PG_62
[53] -> DD_USER_PG_53 — [63] -> DF_USER_PG_63
[54] -> DD_USER_PG_54 — [64] -> DF_USER_PG_64
[55] -> DD_USER_PG_55 — [65] -> DF_USER_PG_65
[56] -> DD_USER_PG_56 — [66] -> DF_USER_PG_66
[57] -> DD_USER_PG_57 — [67] -> DF_USER_PG_67
[58] -> DD_USER_PG_58 — [68] -> DF_USER_PG_68
[59] -> DD_USER_PG_59 — [69] -> DF_USER_PG_69

VarWChar

50

✓

DFP_DY_RULE

Similar to DFP_DX_RULE

VarWChar

50

✓

DFP_DZ_RULE

Similar to DFP_DX_RULE

VarWChar

50

✓

DFP_DW_MIN

Minimum door width/height for this fixing point (left/right or top/bottom fixing point)

Single

4

✓

0
​

DFP_DW_MAX

Maximum door width/height for this fixing point (left/right or top/bottom fixing point).

Double

9

✓

0
​

DFP_P2_DELTA_DX

Only needed if anchor rails at each door fixing point. The anchor rail position and size are determined.

Double

9

✓

0
​

DFP_P2_DELTA_DY

Only needed if anchor rails at each door fixing point. The anchor rail position and size are determined.

Double

9

✓

0
​

DFP_P2_DELTA_DZ

Only needed if anchor rails at each door fixing point. The anchor rail position and size are determined.

Double

9

✓

0
​

DFP_AR_RID

Related to: AR_RID

Integer

4

✓

-1
​

DFP_AR_LEN

Double

9

✓

0
​

Did this answer your question?