Column Name | Description | Data Type | Length | Allow Nulls | Default |
DFP_RID | ID-No. of the door fixing point | Integer | 4 |
| 0 |
DFP_GRP | Number of the group of the door fixing point | Integer | 4 | ✓ | 0 |
DFP_IX | Counter for the quantity of the dimension records for the same type of fixing.
| Integer | 4 | ✓ | 0 |
DFP_MODE |
| Integer | 4 | ✓ | 0 |
DFP_TYPE | Type of the door fixing points: 0 - top fixing point 1 - bottom fixing point 2 - left fixing point 3 - right fixing point | SmallInt | 2 | ✓ | 0 |
DFP_DX | Alignment in x-direction. Do not use this field any more for new records. Use DFP_DX_RULE instead. This can dramatically reduce the number of records to be loaded. Fill this field with 0. | Double | 9 | ✓ | 0 |
DFP_DY | Alignment in y-direction. Do not use this field any more for new records. See also DFP_DX. | Double | 9 | ✓ | 0 |
DFP_DZ | Alignment in z-direction. Do not use this field any more for new records. See also DFP_DX. | Single | 4 | ✓ | 0 |
DFP_DX_RULE | Instead of filling fixed DFP_DX values, you may enter a rule into this field. You can use the same syntax as it is allowed as profile parameters. Example: It is, for instance, very common that a fixing point is at DW/2 - 100 mm (from the center of the door). In this case you may enter the following rule in the DFP_DX_RULE field: 0.5*[3]-100
You can use the standard profile parameters for door fixing points, especially: [3] = Door width [7] = Door height [4] = P2_DELTA_DX If you want to re-use door parameters at the fixing points, you need to use the mapped door fixing point parameters instead (limited to 10 parameters, see below). Door User Parameter — Internally mapped to Door Fixing point parameter | VarWChar | 50 | ✓ |
|
DFP_DY_RULE | Similar to DFP_DX_RULE | VarWChar | 50 | ✓ |
|
DFP_DZ_RULE | Similar to DFP_DX_RULE | VarWChar | 50 | ✓ |
|
DFP_DW_MIN | Minimum door width/height for this fixing point (left/right or top/bottom fixing point) | Single | 4 | ✓ | 0 |
DFP_DW_MAX | Maximum door width/height for this fixing point (left/right or top/bottom fixing point). | Double | 9 | ✓ | 0 |
DFP_P2_DELTA_DX | Only needed if anchor rails at each door fixing point. The anchor rail position and size are determined. | Double | 9 | ✓ | 0 |
DFP_P2_DELTA_DY | Only needed if anchor rails at each door fixing point. The anchor rail position and size are determined. | Double | 9 | ✓ | 0 |
DFP_P2_DELTA_DZ | Only needed if anchor rails at each door fixing point. The anchor rail position and size are determined. | Double | 9 | ✓ | 0 |
DFP_AR_RID | Related to: AR_RID | Integer | 4 | ✓ | -1 |
DFP_AR_LEN |
| Double | 9 | ✓ | 0 |
L_DoorFixingPointTab
Written by Julien
