The Input Matrix is the Excel file you fill in to create LD3 templates with Builder. Download it with Download Sample Duty Table, enter your elevator data, and upload it again.
A general elevator reference model in the background uses your values to create the 3D elevator models, the drawings and additional data. This page lists all columns and the values they take.
How the file is built
Tabs: the sample has four tabs: MR_Metric and MR_Imperial for elevators with machine room, MRL_Metric and MRL_Imperial for elevators without machine room. You can rename or delete tabs you don't need, and add as many tabs as you like. The tab names don't have to follow a rule. After the upload, Builder lists each tab, and you choose which ones to build.
Header rows 1–3: row 1 groups the columns, row 2 has the column names, row 3 has the internal names, for example
EAOG_PAYLOAD. Don't change or delete these rows. Row 3 in particular is needed to build the elevator model correctly.Data rows: start in row 5. Each row is one complete elevator variant.
Units: use metric units (kg, m/s, m, mm) on metric tabs and imperial units (lb, ft/min, ft, in) on imperial tabs.
Model
Column | Internal name | Data type | What to enter | Metric | Imperial |
Model Name | EAOG_MODELNAME | String | The name of the reference model (RefModel) used to create the LD3 files. It must match the project unit. | EaoGeneric | EaoGenericImp |
File Name | EAOG_FILE_NAME | String | The name of the LD3 file that is created. By default, a formula builds it from the main values: DTC_DESC, Payload, Speed, Entrances, Door Opening Type and Door Width. | TRACTION-1-1-RIGHT-CENTRAL-MR-630-1-1-R2-800 |
|
General elevator data
Column | Internal name | Data type | What to enter | Metric | Imperial |
DTC_DESC | EAOG_DTC_DESC | String | The description of the duty table configuration. It must be the same as the DTC_DESC in the table L_DTColTab of the DigiPara Liftdesigner DataManager. | e.g. TRACTION-2-1-LEFT-CENTRAL-MR | e.g. TRACTION-2-1-LEFT-CENTRAL-MR-IMP |
Project Unit | EAOG_PROJ_UNIT | String | The unit used to create the LD3 files | METRIC | IMPERIAL |
Payload | EAOG_PAYLOAD | Double | The payload | kg, e.g. 630 | lb, e.g. 2100 |
Number of passengers | EAOG_PERSONS | Integer | Calculated automatically from the payload. If the result isn't right, enter the number yourself. | 8 | 13 |
Speed | EAOG_SPEED | Double | The speed | m/s, e.g. 1 | ft/min, e.g. 350 |
Travel max | EAOG_TRAVEL_MAX_M | Double | The maximum travel. Despite the "_M" in the name, imperial tabs use feet. | m, e.g. 30 | ft, e.g. 100 |
Stops max | EAOG_STOPS_MAX | Integer | The maximum number of stops | 30 | 30 |
Car
Column | Internal name | Data type | What to enter | Metric | Imperial |
Car Width | EAOG_CAR_WIDTH | Double | The clear car width | mm, e.g. 1100 | in, e.g. 68 |
Car Depth | EAOG_CAR_DEPTH | Double | The clear car depth | mm, e.g. 1400 | in, e.g. 51 |
Car Height | EAOG_CAR_HEIGHT | Double | The minimum car height | mm, e.g. 2200 | in, e.g. 88 |
Counterweight
Column | Internal name | Data type | What to enter | Values |
CWT Location | EAOG_CWT_SIDE | String | The side of the counterweight. Choose from the list. | LEFT, RIGHT, REAR |
Doors
Column | Internal name | Data type | What to enter | Metric | Imperial |
Entrances | EAOG_ENTRANCES | Integer | 1 = front entrance only, 2 = front and rear entrances | 1 | 1 |
Door Opening Type | EAOG_DOORTYPE | String | The door type. Choose from the list (see Door opening types). | e.g. R2 | e.g. R2 |
Door Width | EAOG_DOOR_WIDTH | Double | The door width. Use one of the widths available for the door type (see Door opening types). | mm, e.g. 800 | in, e.g. 36 |
Door Height | EAOG_DOOR_HEIGHT | Double | The minimum door height | mm, e.g. 2000 | in, e.g. 84 |
Car height/Door height combination | EAOG_CH_DH_COMBINATIONS | String | Further combinations of car height and door height, in addition to Car Height and Door Height. Format: | (2200,2100);(2200,2200) | (88,86);(88,88) |
Note: The combinations in Car height/Door height combination don't create extra LD3 files. If a car height differs from Car Height, EAO adjusts the shaft head: it increases or decreases it accordingly.
Door opening types
All door types are sliding doors. The widths are in steps of 100 mm.
Value | Panels | Opening | Door widths, metric (mm) | Door widths, imperial (in) |
L1 | 1 | Left | 700–1500 | 30, 36, 42, 48, 54, 60 |
R1 | 1 | Right | 700–1500 | 30, 36, 42, 48, 54, 60 |
L2 | 2 | Left | 500–2000 | 30, 36, 42, 48, 54, 60 |
R2 | 2 | Right | 500–2000 | 30, 36, 42, 48, 54, 60 |
C2 | 2 | Centre | 500–2000 | 30, 36, 42, 48, 54, 60, 78 |
L3 | 3 | Left | 700–1800 | 30, 36, 42, 48, 54 |
R3 | 3 | Right | 700–1800 | 30, 36, 42, 48, 54 |
C4 | 4 | Centre | 700–3000 | 30, 36, 42, 48, 54, 78 |
C6 | 6 | Centre | 700–3000 | 30, 36, 42, 48, 54, 78 |
Shaft
Column | Internal name | Data type | What to enter | Metric | Imperial |
Shaft Width | EAOG_SHAFT_WIDTH | Double | The clear shaft width | mm, e.g. 1600 | in, e.g. 88 |
Shaft Depth | EAOG_SHAFT_DEPTH | Double | The clear shaft depth | mm, e.g. 1800 | in, e.g. 80 |
Shaft Pit | EAOG_SHAFT_PIT | Double | The pit depth | mm, e.g. 1000 | in, e.g. 60 |
Shaft Pit Reduced | EAOG_SHAFT_PIT_REDUCED | Double | Optional: the alternative, reduced pit depth | mm, e.g. 450 | in, e.g. 40 |
Shaft Head | EAOG_SHAFT_HEAD | Double | The shaft head that goes with the Car Height | mm, e.g. 3400 | in, e.g. 183 |
Shaft Head Reduced | EAOG_SHAFT_HEAD_REDUCED | Double | Optional: the alternative, reduced headroom height | mm, e.g. 3200 | in, e.g. 140 |
Note: If you fill in Shaft Pit Reduced or Shaft Head Reduced, Builder creates extra configurations with the reduced pit, the reduced head, or both. Leave the columns empty if the model has no reduced pit or head.
Machine room
Column | Internal name | Data type | What to enter | Metric | Imperial |
MR Width | EAOG_MR_WIDTH | Double | The machine room width | mm, e.g. 2500 | in, e.g. 88 |
MR Depth | EAOG_MR_DEPTH | Double | The machine room depth | mm, e.g. 1950 | in, e.g. 125 |
MR Height | EAOG_MR_HEIGHT | Double | The machine room height | mm, e.g. 2000 | in, e.g. 90 |
For elevators without machine room (MRL), enter 0 in all three columns.