Skip to main content

Elevator Sample Duty Table: Columns and Values

All columns of the Builder Input Matrix, with units and allowed values.

Written by Sabine Bunese

The Input Matrix is the Excel file you fill in to create LD3 templates with Builder. Download it with Download Sample Duty Table, enter your elevator data, and upload it again.

A general elevator reference model in the background uses your values to create the 3D elevator models, the drawings and additional data. This page lists all columns and the values they take.

How the file is built

  • Tabs: the sample has four tabs: MR_Metric and MR_Imperial for elevators with machine room, MRL_Metric and MRL_Imperial for elevators without machine room. You can rename or delete tabs you don't need, and add as many tabs as you like. The tab names don't have to follow a rule. After the upload, Builder lists each tab, and you choose which ones to build.

  • Header rows 1–3: row 1 groups the columns, row 2 has the column names, row 3 has the internal names, for example EAOG_PAYLOAD. Don't change or delete these rows. Row 3 in particular is needed to build the elevator model correctly.

  • Data rows: start in row 5. Each row is one complete elevator variant.

  • Units: use metric units (kg, m/s, m, mm) on metric tabs and imperial units (lb, ft/min, ft, in) on imperial tabs.

Model

Column

Internal name

Data type

What to enter

Metric

Imperial

Model Name

EAOG_MODELNAME

String

The name of the reference model (RefModel) used to create the LD3 files. It must match the project unit.

EaoGeneric

EaoGenericImp

File Name

EAOG_FILE_NAME

String

The name of the LD3 file that is created. By default, a formula builds it from the main values: DTC_DESC, Payload, Speed, Entrances, Door Opening Type and Door Width.

TRACTION-1-1-RIGHT-CENTRAL-MR-630-1-1-R2-800

General elevator data

Column

Internal name

Data type

What to enter

Metric

Imperial

DTC_DESC

EAOG_DTC_DESC

String

The description of the duty table configuration. It must be the same as the DTC_DESC in the table L_DTColTab of the DigiPara Liftdesigner DataManager.

e.g. TRACTION-2-1-LEFT-CENTRAL-MR

e.g. TRACTION-2-1-LEFT-CENTRAL-MR-IMP

Project Unit

EAOG_PROJ_UNIT

String

The unit used to create the LD3 files

METRIC

IMPERIAL

Payload

EAOG_PAYLOAD

Double

The payload

kg, e.g. 630

lb, e.g. 2100

Number of passengers

EAOG_PERSONS

Integer

Calculated automatically from the payload. If the result isn't right, enter the number yourself.

8

13

Speed

EAOG_SPEED

Double

The speed

m/s, e.g. 1

ft/min, e.g. 350

Travel max

EAOG_TRAVEL_MAX_M

Double

The maximum travel. Despite the "_M" in the name, imperial tabs use feet.

m, e.g. 30

ft, e.g. 100

Stops max

EAOG_STOPS_MAX

Integer

The maximum number of stops

30

30

Car

Column

Internal name

Data type

What to enter

Metric

Imperial

Car Width

EAOG_CAR_WIDTH

Double

The clear car width

mm, e.g. 1100

in, e.g. 68

Car Depth

EAOG_CAR_DEPTH

Double

The clear car depth

mm, e.g. 1400

in, e.g. 51

Car Height

EAOG_CAR_HEIGHT

Double

The minimum car height

mm, e.g. 2200

in, e.g. 88

Counterweight

Column

Internal name

Data type

What to enter

Values

CWT Location

EAOG_CWT_SIDE

String

The side of the counterweight. Choose from the list.

LEFT, RIGHT, REAR

Doors

Column

Internal name

Data type

What to enter

Metric

Imperial

Entrances

EAOG_ENTRANCES

Integer

1 = front entrance only, 2 = front and rear entrances

1

1

Door Opening Type

EAOG_DOORTYPE

String

The door type. Choose from the list (see Door opening types).

e.g. R2

e.g. R2

Door Width

EAOG_DOOR_WIDTH

Double

The door width. Use one of the widths available for the door type (see Door opening types).

mm, e.g. 800

in, e.g. 36

Door Height

EAOG_DOOR_HEIGHT

Double

The minimum door height

mm, e.g. 2000

in, e.g. 84

Car height/Door height combination

EAOG_CH_DH_COMBINATIONS

String

Further combinations of car height and door height, in addition to Car Height and Door Height. Format: (car height,door height);(car height,door height);…. Leave it empty if there are no other combinations.

(2200,2100);(2200,2200)

(88,86);(88,88)

Note: The combinations in Car height/Door height combination don't create extra LD3 files. If a car height differs from Car Height, EAO adjusts the shaft head: it increases or decreases it accordingly.

Door opening types

All door types are sliding doors. The widths are in steps of 100 mm.

Value

Panels

Opening

Door widths, metric (mm)

Door widths, imperial (in)

L1

1

Left

700–1500

30, 36, 42, 48, 54, 60

R1

1

Right

700–1500

30, 36, 42, 48, 54, 60

L2

2

Left

500–2000

30, 36, 42, 48, 54, 60

R2

2

Right

500–2000

30, 36, 42, 48, 54, 60

C2

2

Centre

500–2000

30, 36, 42, 48, 54, 60, 78

L3

3

Left

700–1800

30, 36, 42, 48, 54

R3

3

Right

700–1800

30, 36, 42, 48, 54

C4

4

Centre

700–3000

30, 36, 42, 48, 54, 78

C6

6

Centre

700–3000

30, 36, 42, 48, 54, 78

Shaft

Column

Internal name

Data type

What to enter

Metric

Imperial

Shaft Width

EAOG_SHAFT_WIDTH

Double

The clear shaft width

mm, e.g. 1600

in, e.g. 88

Shaft Depth

EAOG_SHAFT_DEPTH

Double

The clear shaft depth

mm, e.g. 1800

in, e.g. 80

Shaft Pit

EAOG_SHAFT_PIT

Double

The pit depth

mm, e.g. 1000

in, e.g. 60

Shaft Pit Reduced

EAOG_SHAFT_PIT_REDUCED

Double

Optional: the alternative, reduced pit depth

mm, e.g. 450

in, e.g. 40

Shaft Head

EAOG_SHAFT_HEAD

Double

The shaft head that goes with the Car Height

mm, e.g. 3400

in, e.g. 183

Shaft Head Reduced

EAOG_SHAFT_HEAD_REDUCED

Double

Optional: the alternative, reduced headroom height

mm, e.g. 3200

in, e.g. 140

Note: If you fill in Shaft Pit Reduced or Shaft Head Reduced, Builder creates extra configurations with the reduced pit, the reduced head, or both. Leave the columns empty if the model has no reduced pit or head.

Machine room

Column

Internal name

Data type

What to enter

Metric

Imperial

MR Width

EAOG_MR_WIDTH

Double

The machine room width

mm, e.g. 2500

in, e.g. 88

MR Depth

EAOG_MR_DEPTH

Double

The machine room depth

mm, e.g. 1950

in, e.g. 125

MR Height

EAOG_MR_HEIGHT

Double

The machine room height

mm, e.g. 2000

in, e.g. 90

For elevators without machine room (MRL), enter 0 in all three columns.

Did this answer your question?