Prerequisites
The new landing door is open in the Developer Work Area.
Steps
1.) Locate the Explanation of Parameters and Values. The reference developer .dwg file for a door's 3D parameters is stored at C:\ProgramData\DigiPara\dcc\DataPool\developer.
2.) Read through each typical 3D parameter group for the landing door before editing values. Use the reference drawing snippets and images in DigiPara Liftdesigner Datamanager to understand what each of the following parameter groups controls:
Installation Position: DT_INSTALL_Y0_MIN = -50, DT_INSTALL_Y0_MAX = 250, DT_INSTALL_Y0_DEF = -50
Door Head (note:
DT_KLandDT_KRapply to car doors only): DT_K = 210, DT_K_Y =60
Settings for Compatibility
Opening Type & Door Panels: DT_B_Y = 49
Length of Sill
Ghost Panels & Sill Dimensions (ghost panels apply to car doors only): DT_S_Y = 54, DT_S_Z = 30
Door Frame Size left / right in X-Direction
Door Frame Size left / right in Y-Direction
Main Characteristic & Apron Size: DT_DRAW_TYPE = 73
Door Frame left / right – Jamb Width
Entry Pocket — edited via the
DD_DESCcolumn; ifDD_POCKET_DYis0, the pocket is only displayed once you set up a depth for it in DigiPara Liftdesigner.
Adjust DD_DESC. Update the Designations column to reflect the new door widths.
Result
You understand what each of the landing door's key 3D parameters controls, before editing its geometry in the following steps.