Set the car size, the counterweight, the doors and the door front of an elevator. The values you enter are requirements: EAO picks the catalog model that meets them, and updates the shaft and the drawing.
Prerequisites
You are signed in to EAO
The elevator group is open in the elevator editor
The elevator is set to Catalog
Set the cabin size
In the elevator's column, click CABIN to unfold it.
The line at the top shows what the current model delivers.Under CAR DIMENSIONS, enter a Min. and Max. value for Car Width and Car Depth, if needed.
Choose the Proportions of the car, or leave Any:
Wide car: the car is wider than it is deep. Wide cars usually meet wheelchair accessibility requirements.
Deep car: the car is at least as deep as it is wide.
Set the Car Height: choose ≥ (at least) or = (exactly), then a value.
Under ADDITIONAL ACCESS REQUIREMENTS, select what the car must take:
Wheel Chair: the door is at least 900 mm wide.
Bed: the car is at least 2,100 mm deep.
Result: EAO picks the model that fits your requirements. The CABIN row shows the new car width and depth, and the shaft and drawing are updated.
Change the counterweight
Click COUNTERWEIGHT to unfold it.
The line at the top shows the current position and whether there is a safety gear.Under COUNTERWEIGHT LOCATION, click the side you need:
Left: entrances at the front and rear are possible. The landing doors open to the left or in the center.
Rear: front entrance only. All door opening types are possible, depending on the catalog.
Right: entrances at the front and rear are possible. The landing doors open to the right or in the center.
Under SAFETY GEAR, choose With, Without or Any. This option is only available if the catalog has models both with and without a counterweight safety gear.
Result: The COUNTERWEIGHT row shows the new side. EAO updates the shaft and the drawing. The door opening direction may change as well, because the counterweight should match it.
NOTE: A greyed-out option isn't possible with the current settings. For example, a rear counterweight isn't possible with entrances at the front and rear.
Set the entrances
Click ENTRANCES to unfold it.
The line at the top shows the current doors.Under REQUIREMENTS, choose the layout:
left icon: entrance at the front only
right icon: entrances at the front and rear. This is only possible with the counterweight on the left or right.
Under FRONT/REAR ENTRANCE, set what you need:
Door Height and Door Width: choose ≥ or =, then a value
Door Opening: Left, Center, Right or Any. The options depend on the counterweight side.
Door Pocket Installation: Allowed or Not Allowed. With a door pocket, the landing door sits in a wall niche, which changes the shaft depth.
Result: The line at the top of ENTRANCES shows the new doors. With front and rear entrances, the shaft gets deeper to fit the second door.
NOTE: When you choose front and rear entrances, the rear doors are switched on for all floors. To change which floors have a rear door, use the STOPS section. You only set the opening type of the front door; the rear door is mirrored automatically.
NOTE: Not every model offers front and rear entrances. If the catalog has none, the elevator is marked Invalid, ENTRANCES shows FILTERINVALID and the group is put on hold.
Choose the door front
The door front is the design of the landing door portal. You can choose one design for the typical floors and another one for the main floor, separately for each elevator.
Click DOOR FRONT to unfold it.
Under Typical Floors, click the door front design for all floors except the main floor.
Under Main floor, click the door front design for the main floor. The number in brackets is the main floor.
Result: The selected designs are outlined. The DOOR FRONT row shows the door front in use, and the drawing is updated.
NOTE: The door front is part of the elevator's configuration, not a filter. The main floor is set in the building wizard; all other floors are typical floors. If an elevator doesn't stop at the main floor, you can't choose a main floor design for it.