An elevator group you plan in Revit lives in two places: its data is saved with your EAO contract, and its families are in your Revit model. The add-in only changes the Revit model when you update the group.
Two copies of one elevator group
| Elevatorarchitect Online | Your Revit project |
What is stored | The elevator data: requirements, model, cabin, entrances, shaft, stops | The elevator families (Generic Models) built from that data |
Where you find it | My Projects › Revit Plugin Root › site › building › group | The add-in panel and the Project Browser (Families › Generic Models) |
When it changes | As soon as you save in the configurator — in Revit or in the browser | Only when you click Update (or Update location in Revit for the position) |
What each button does
You click | EAO data | Revit model |
Save and close in the configurator | Saved | Not changed |
Update in the configurator | Saved | Group rebuilt |
Update for a group in the panel | — | Group rebuilt with the current EAO data |
Update all in the panel | — | All groups rebuilt |
Update location in Revit | — | Group moved to X, Y, Angle; families stay |
What happens during an update
An update replaces the group's families: the add-in deletes the families it imported before and loads them again with the current data, LOD and family prefix. Update Progress lists each family as it loads. The more elevators and the higher the LOD, the more families and the longer it takes.
Changes made in Elevatorarchitect Online
You can open the same group in Elevatorarchitect Online in your browser and change it there. The Revit model keeps the old state until you click Update for the group in the add-in panel.
Floors come from Revit
The floors of the building are your Revit levels marked as Building Story. The elevator's stops are chosen from these levels. To add or remove floors, change the levels in Revit.