Configure an Escalator or Moving Walk

Change arrangement, parameters, landing and truss lengths, apply them with Update Model, and fix a group on hold.

Written by Sabine Bunese

After the wizard, you fine-tune the installation in the escalator configurator: change the arrangement or parameters, move the lower landing, and set the truss lengths of each unit. Your changes reach the model only when you click Update Model.

Prerequisites

  • You are signed in to EAO

  • The escalator project is open in the configurator

Change the group settings

  1. Click a section to unfold it:

    • ARRANGEMENT: the same tiles as in the wizard. Changing the arrangement changes the number of unit cards.

    • PARAMETERS: the same drop-down lists as in step 4 of the wizard. Any means EAO doesn't filter on the value.

    • FLOORS: choose the lower landing. The upper landing and the travel follow from the building and can't be changed here.

  2. Change the values you need.
    A PENDING UPDATE label appears on the group settings.

  3. Click Update Model.

Set the truss lengths of a unit

Each unit has its own card and is edited on its own.

  1. In the unit card, enter the Upper truss length and Lower truss length in millimetres.

    The grey range next to each field is the window the catalog allows. It comes from the minimum and maximum on the duty-table row of the model.

  2. Click Update Model.

If a value is outside the window, the field is outlined in red, the range turns red, and Update Model is disabled until you correct the value.

Result: The PENDING UPDATE labels disappear and the viewer shows the new model.

TIP: Update Model takes a while. Collect several changes and update once.

Horizontal moving walks

A horizontal moving walk is configured in the same configurator, with three differences:

  • The arrangement is Single or Parallel only. Each unit is a lane.

  • There are no landings and no travel. The section is called FLOOR and holds the floor and the horizontal length, with the window the catalog allows next to it.

  • PARAMETERS holds only step width and speed.

If the group goes on hold

If the model no longer meets the requirements, a red banner appears above the configurator. The section that causes it is marked red, and the breadcrumb shows a warning triangle.

  1. Open the marked section.
    It names the value that can't be met.

  2. Choose one of the two options:

    • Use … instead takes the nearest value the catalog can deliver.

    • Set to Any stops filtering on this parameter.

  3. Click Update Model.

Result: Once the model fits again, the banner disappears and EAO generates the drawings.