Skip to main content

Change the Requirements or the Catalog

Widen or narrow the requirements, choose another model type, change the catalog, and fix a group that is on hold.

Written by Sabine Bunese

The requirements and the catalog decide which elevator models EAO can offer for a group. Widen the requirements when no model fits, narrow them to get a more specific result, or change the catalog to plan with another manufacturer.

Prerequisites

  • You are signed in to EAO

  • The elevator group is open in the elevator editor

Adjust the requirements

  1. In an elevator's column, click REQUIREMENTS to unfold it. The filters are grouped by where they come from:

    • SITE FILTER: sales region, seismic zone and model unit, taken from the site

    • BUILDING FILTER: the building type

    • ELEVATOR GROUP FILTER: the catalog you selected

    • MODEL FILTER: maximum travel, maximum stops and cabin access, plus every requirement you set yourself in the other sections, for example Elevator Type or Shaft Depth

    A green tick next to a filter means that the chosen model meets it.

  2. To widen the search, clear the check box in front of a filter. To narrow it again, select the check box. Greyed-out check boxes can't be changed.

  3. For requirements you set yourself:

    • To remove one, click × in front of it.

    • To change its priority, drag it up or down with the arrows on the right. EAO meets the requirements at the top first.

Result: EAO searches the catalog again and shows the model that best fits the active requirements.

NOTE: Switching a filter off is the first thing to try when no model matches.

Choose another model type

  1. Click MODEL to unfold it.
    The line at the top describes the current model.

  2. Choose what you need:

    • ELEVATOR TYPE: Any, Traction Elevator or Hydraulic Elevator

    • MACHINE ROOM: Any, Without or With

    • MODEL SELECTION: Any, or a specific model family of the catalog

Result: EAO picks a model that matches your choice. Your choice is added as a requirement under REQUIREMENTS.

NOTE: After choosing a different model, check the other requirements. Some may need to be adapted.

Change the catalog

The catalog applies to the whole group. You can't use different catalogs for elevators in the same group.

  1. In the top right of the editor, click CHANGE CATALOG.
    The CHANGE ELEVATOR BRAND window opens. On the left, SELECTED BRAND shows the current catalog.

  2. Find the brand under PREFERRED ELEVATOR BRANDS or MORE ELEVATOR BRANDS. To add a brand to your preferred brands, click its star.

  3. Optional: click the arrow next to a model to see its car size and payload.

  4. Point at the brand card and click Select. The button changes to Selected.

  5. Click finish.

Result: The editor shows the new catalog next to CHANGE CATALOG. EAO looks for a matching model again for every elevator in the group, so model, door size and shaft size can change. Your requirements and settings, such as names, counterweight side and entrances, are kept.

If the group goes on hold

If the catalog can't meet all your requirements, for example after you change the catalog, the elevator group is put ON HOLD:

  • A red banner shows how many elevators are affected. EAO doesn't generate 2D, 3D, BIM or export for the group until the issue is resolved.

  • Each affected elevator shows Invalid and the note "One requirement could not be met — the values shown answer the others."

  • The section that caused it is marked with FILTERINVALID.

To fix it, do one of these:

  1. Open the marked section and set the requirement back, or choose a less strict value.

  2. Under REQUIREMENTS, switch off the matching filter.

  3. Click CHANGE CATALOG and choose a catalog with a model that meets the requirement.

Result: When every elevator is valid again, the banner disappears and EAO creates the drawings and the BIM model again.

Did this answer your question?