Travel Max: When the Building Is Taller Than the Catalog

What Travel Max means, why a group goes on hold when no model reaches the travel, and what Catalog: Max Rise Exceeded means.

Written by Sabine Bunese

Every elevator model in a catalog has a maximum travel (Travel Max) and a maximum number of stops (Stops Max). The travel of your elevator group follows from the building: it is the height from the lowest to the highest stop. EAO only picks models that reach this travel.

Where you see the travel

  • In the wizard: step 3 of NEW ELEVATOR PROJECT shows TRAVEL (MM) under the stops. You can't edit it; it changes when you change the top or bottom stop.

  • In REQUIREMENTS: under MODEL FILTER, the rows Travel Max and Stops Max show what the model must reach.

  • In STOPS: the section shows the travel of the elevator and the limits of the selected model.

When no model of the catalog reaches the travel

If the building is taller than every model of the group's catalog can serve, EAO can't meet the Travel Max requirement. EAO then:

  • marks the elevator Invalid and STOPS with FILTERINVALID

  • puts the group on hold: no 2D, 3D, BIM or export is created

  • shows a box under MODEL FILTER with the button Resolve travel

You have two ways out: keep the supplier and use its fastest elevator, or change the catalog.

Recommended, Possible, Not suitable

When you change the catalog from the configurator and check the 'Ignore travel constraints' box, EAO rates each catalog for your travel:

Rating

Meaning

Recommended

In catalog for this travel. A model reaches the travel.

Possible

Beyond catalog, needs OEM confirmation. No model reaches the travel, but the fastest elevator of this catalog serves it in 120 s or less, or runs at 6 m/s or faster.

Not suitable

The fastest elevator is too slow for this travel (it would take more than 120 s).

NOTE: The number of stops is shown, not rated. A fast model with fewer stops stays Possible; Stops Max is then switched off too, and the manufacturer confirms both.

Catalog: Max Rise Exceeded

If you keep a Possible catalog, the elevator is buildable, but only beyond the catalog. EAO shows this clearly:

  • The mode label reads Catalog: Max Rise Exceeded instead of Catalog.

  • MODEL shows Needs OEM confirmation.

  • STOPS shows Max Rise Exceeded and a line, for example: "Catalog: Max Rise Exceeded — Travel 72 m > Travel Max 27 m · needs OEM confirmation".

What Resolve travel changes in the requirements

Requirement

After Resolve travel

Travel Max

Switched off (parked). EAO keeps the value and shows "Relaxed — replaced by Min. Speed …".

Min. Speed

Added in place of Travel Max: the speed of the catalog's fastest elevator for this project. You can't change it.

Stops Max

Stays if the fast model reaches your stops. Otherwise it is switched off too.

Your own Speed requirement

Parked while Min. Speed applies.

Model

The fastest model, with its own payload, cabin and shaft.

NOTE: A parked requirement keeps its value, but isn't a search criterion while Resolve travel applies. Undo brings everything back.