If your building is taller than any model of the group's catalog can serve, EAO puts the group on hold. Resolve the travel to continue: keep the supplier and use its fastest elevator, or change to a catalog that reaches the travel.
Prerequisites
You are signed in to EAO
The elevator group is open in the elevator editor
The group shows Group on hold, and the card says "Travel set aside — the values shown answer only the site filters."
Check why the travel was set aside
On the elevator card, unfold REQUIREMENTS.
Under MODEL FILTER, read the box under the Travel Max row, for example:
Click Resolve travel. The dialog Stay with catalog? opens.
The dialog shows the fastest elevator of the catalog for this project and whether it can serve your travel.
It also lists what will change (Travel Max switched off, Min. Speed added, model changed) and the rating. Choose one of the two options below.
Option 1: Keep the supplier and use its fastest elevator
In the dialog, leave Apply to all units of this group above the ceiling selected if all elevators of the group should be resolved.
Click Keep catalog — use fastest lift.
Result:
The group is no longer on hold, and drawings and exports are created again.
A green box reads Resolved — Possible, needs final OEM confirmation.
The mode label reads Catalog: Max Rise Exceeded, MODEL shows Needs OEM confirmation, and STOPS shows Max Rise Exceeded.
In REQUIREMENTS, Travel Max is struck through with "Relaxed — replaced by Min. Speed ≥ 1 m/s, the fastest … lift for this project", and a new Min. Speed row appears.
NOTE: Confirm the configuration with the manufacturer before you rely on it.
Undo the resolve
In REQUIREMENTS, in the green box, click Undo.
Result: Travel Max and Stops Max are active again and Min. Speed is gone. The travel is still too high, so the group is on hold again.
Option 2: Change to another catalog
In the dialog, click Change catalog instead. CHANGE ELEVATOR BRAND opens with the catalogs sorted by rating:
RECOMMENDED — in catalog for this travel
POSSIBLE — beyond catalog, needs OEM confirmation
NOT SUITABLE — fastest elevator too slow for this travel (only shown if you select Show Not suitable)
Use the check boxes at the top to filter: Ignore travel constraints, Show Possible, Show Not suitable, Favourites only.
Check the catalog cards. Each shows the fastest speed and the catalog's travel limit.
Select a catalog. On the left, under SELECTED BRAND, EAO explains what finish does.
Click finish.
Result: EAO changes the catalog for the whole group.
With a Recommended catalog, the elevators are selected as usual and show Catalog.
With a Possible catalog, every elevator above the catalog's limit gets the fastest model and shows Catalog: Max Rise Exceeded.
Note: If no catalog can be selected instead (for example in a white label configurator with one supplier), the dialog is called Resolve travel? and the button Use fastest lift. If even the fastest elevator is too slow, reduce the travel in the building's floor list (Reduce travel).



