In a new building, you choose the elevator and the shaft follows from it. In an existing building, the shaft is already built. Its width, depth, headroom and pit are fixed, and the elevator has to fit inside them.
The option Shaft is given (existing building) tells EAO that you are in the second situation. EAO then treats your four shaft measurements as upper limits and looks for an elevator that still fits.
EAO picks the largest elevator that fits
For an existing shaft, EAO picks the largest catalog elevator that fits the shaft, not the smallest one that meets your requirements. Every other search in EAO works the other way round. This is on purpose: the shaft is already there, so you want to use the space.
The four measurements are upper limits
Measurement | Where you enter it in the wizard |
Available width | Step 2, EXISTING SHAFT — CROSS-SECTION |
Available depth | Step 2, EXISTING SHAFT — CROSS-SECTION |
Available headroom | Step 3, EXISTING SHAFT — HEADROOM & PIT |
Available pit | Step 3, EXISTING SHAFT — HEADROOM & PIT |
Each field has a ≤ in front of it: the elevator may need less, never more. Measure the shaft as built. If you are unsure of a value, enter the smaller one. A value that is too optimistic returns elevators that can't be installed.
Headroom and pit often decide more than width and depth. A shaft can be wide enough and still be ruled out because the pit is too shallow.
Where you see the existing shaft
You enter the measurements once. They appear in two places:
In the NEW ELEVATOR PROJECT wizard, when you create the elevator group. The measurements already filter the elevator brands in step 4.
In the elevator editor, in the shaft section. The section is now called EXISTING SHAFT and is tinted, so you can see at a glance that the shaft is given.
NOTE: The option is set per elevator group. It has nothing to do with the building type of the building.
The fit badge
The collapsed EXISTING SHAFT section shows a badge that compares the elevator with the shaft:
Badge | Meaning |
matches given | Every dimension of the elevator equals the given measurement. |
differs from given | The elevator is smaller than the shaft in at least one dimension. This is normal: you have room to spare. |
exceeds given | At least one dimension is larger than the shaft. This elevator can't be installed. A red dot also appears beside the section name. |
NOTE: differs from given is an observation. exceeds given is a stop
Catalog and Special
In Catalog mode, the shaft section is a search: you see the four limits and the Best fit — the model EAO chose, the shaft it needs and the room to spare in each direction.
In Special mode, the shaft section compares the elevator with the building in a table: CURRENT, GIVEN and the difference Δ. Here you adapt the elevator to the shaft.
Your own shaft filters are parked
Without the existing-shaft option, the shaft section offers Min: and Max: values for Shaft Width and Shaft Depth, and Reduced Head and Reduced Pit under ADDITIONAL SHAFT REQUIREMENTS. When you switch the existing shaft on, your own shaft filters are kept with their values but no longer used as search criteria. EAO shows "Parked while the existing shaft applies" under them.
What happens when you switch it off
When you clear Shaft is given (existing building), EAO goes back to the normal search and returns the smallest elevator that meets your requirements.