When the elevator goes into a shaft that already exists, enter the measured shaft. EAO then looks for the largest catalog elevator that fits. You can compare the elevator with the shaft and adjust it until it fits.
Prerequisites
You are signed in to EAO
You have a building with floors
You have the four measurements of the shaft as built: width, depth, headroom and pit, in mm
Enter the shaft when you create the elevator group
Enter the shaft in the wizard, before you choose a brand. The brands you are offered are already filtered by it.
On the building page, click NEW ELEVATOR PROJECT.
In ELEVATOR GROUP NAME, enter a name.
Select Shaft is given (existing building), then click next.
Set the main requirements and the entrance sides as usual.
Under EXISTING SHAFT — CROSS-SECTION, enter AVAILABLE WIDTH (MM) and AVAILABLE DEPTH (MM), then click next.
Check the stops. Under EXISTING SHAFT — HEADROOM & PIT, enter AVAILABLE HEADROOM (MM) and AVAILABLE PIT (MM), then click next.
Under ELEVATOR BRAND, choose a brand. A brand that can't meet all your requirements shows No model matches all requirements. You can still select it, but the model on the card meets only some of your requirements.
Point at the brand card, click Select, then click finish.
Result: EAO creates the group and opens the elevator editor. The shaft section is called EXISTING SHAFT and shows a fit badge, for example differs from given.
TIP: You don't have to decide in the wizard. You can select Shaft is given (existing building) later in the elevator editor: unfold the shaft section and select the check box there.
Check the best fit
On the elevator card, unfold EXISTING SHAFT. The elevator must be in Catalog mode.
Under SHAFT DIMENSIONS, check the four limits: Available width, Available depth, Available headroom and Available pit.
Read the Best fit line.
TIP: Check the spare values, not only the model name. A few millimetres of spare room is worth a second look on site.
Change a limit
Unfold EXISTING SHAFT.
Change one of the four values.
Result: EAO searches again. A smaller shaft takes a smaller elevator, so payload, cabin and doors can change too.
Compare the elevator with the shaft (Special)
Next to the elevator's name, click Special.
Unfold EXISTING SHAFT. The table shows four rows (Shaft width, Shaft depth, Shaft head, Shaft pit) and four columns:
CURRENT: what this elevator needs. A pencil icon marks the values you can change.
GIVEN: the measured shaft (read-only).
Δ: the difference. Negative means room to spare, zero is an exact match, positive means the elevator doesn't fit.
Adjust a value to the given measurement
In CURRENT, click the pencil icon next to the value. An editor opens under the row.
Click Adjust to given. The link shows how much the value will change.
Click Apply to keep the change, or Cancel to drop it.
Result: The value equals the given measurement and Δ is 0. The catalog value stays visible, struck through.
To go back to the catalog value, click the pencil icon again and click Reset to ….
When a value doesn't fit
If you enter a value larger than the shaft, EAO shows a message under the field. Δ turns red, a red dot appears beside the section name and the badge changes to exceeds given. Click Adjust to given (−200 mm) to go back in one click.
Correct the measured shaft
If you measured wrongly, you don't have to start again.
Unfold EXISTING SHAFT in Special mode.
Above the table, click ✎ Edit given. The GIVEN column becomes editable.
Change the values and click ✓ Done.
Result: Δ and the badge are recalculated. The elevator itself doesn't change.
Switch the existing shaft off
Unfold the shaft section.
Clear Shaft is given (existing building).
Result: The section is called SHAFT again. It shows Min: and Max: for Shaft Width and Shaft Depth, and Reduced Head and Reduced Pit under ADDITIONAL SHAFT REQUIREMENTS. EAO now returns the smallest elevator that meets your requirements, so the elevator can become much smaller. Your four measurements are kept. Select the check box again to get them back.